Release 7.2 |
Added
compatibility with z/OS 1.5 and above by adding a 31-bit load
library. Two load libraries are now supplied with the
product. The 24-bit load library must be used with OS/390
and z/OS 1.4 and below and the 31-bit load library must be used
with z/OS 1.5 and above, in order to avoid a S0C4 abend. |
|
|
For z/OS 1.5 and
above, added the fields to the LCTPCSI Catalog Search Interface
program that were missing in earlier z/OS releases of the CSI.
Those fields are Total Records, CI and CA Splits, and CI and CA
Freespace percentages. |
|
|
Fixed a VSE
problem with the Volume Summary report when 3390 Model 9 DASD is
used. |
|
|
Fixed an abend or
a mostly blank print line when some numeric fields from IDCAMS
are “---INVALID”. |
|
Download Listcat Plus 7.2
upgrade |
|
|
Release 7.1 |
Enhanced the LISTCAT PLUS report as
follows:
- Added an option to only include
the dataset if it has a tuning message.
- Added the choice of date formats
(Gregorian MMDDYY or Julian YY.DDD) for date created or updated.
- Added user-specified thresholds
for the following tuning messages:
- Dataset has not been updated for
XXXX days.
- No records have been inserted in
this dataset in XXX days.
- Dataset has exceeded XXX
extents.
- Added the capability to sort the
report by catalog (and then dataset name).
- Added System Managed Storage (SMS)
fields Storageclass, Managementclass, Dataclass, and Lbackup
date to the non-VSAM report.
|
|
|
Added a new report that runs MUCH
FASTER than IDCAMS or LISTCAT PLUS because it uses the new MVS
Catalog Search Interface (CSI). The report is similar to LISTCAT
PLUS except that it does not contain fields that are not
available to the CSI. Fields in LISTCAT PLUS that are not in the
CSI report are CI and CA split counts, CI and CA initial
Freespace values, and total number of records. |
|
|
Added OR capability to the ADHOC
report. Multiple conditions per field can now be specified. ANDs
and/or ORs can be used in combination. For example, CI-SPLITS >
1000 or CA-SPLITS > 50 and EXTENTS > 15 and EXCP > 99999. |
|
|
Made new fields available to the ADHOC
report including: Insert to CI and CA split ratios, dataset
owner, Storageclass, Managementclass, Dataclass, LastBackup
date, and the first and second qualifiers of the dataset name |
|
|
Release 7.0 |
Corrects the wrong century in the
REPORT file field CREATE-CENTURY for Non-VSAM files only. |
|
|
Release 6.9 |
Added year 2000 compatibility. Added
2-byte century to date fields. Expanded SORT-FILE and HISTORY
records from 506 to 508 characters. A conversion program LCTPHIS
is included. |
|
Expanded REPORT file (input to Adhoc
Report Writer) from 430 to 530 characters per record. |
|
Added four new options to the
parameter card. Col. 37
'Y' or blank = Print the input parameters
'N' = Do not print the input parameters
Col. 38
'Y' or blank = Print the Catalog Legend report
‘N' = Do not print the Catalog Legend report
Col 39
'Y' or blank = Print the Volume Summary report
'N' = Do not print the Volume Summary report
Col. 40
'Y' or blank = Print the VSAM Catalog Listing
‘N' = Do not print the VSAM Catalog Listing
Note:
If all four columns are blank, all four of the reports will print
(as in prior releases). |
|
Changed the print record default size
from 132 to 133 by including the carriage control character.
Compiles must now be done with the NOADV option. |
|
Now indicate file type 'L' for Linear
VSAM files. |
|
Added an option on the dataset
selection input card to 'exclude' files from selection. |